/ 1
1769-IT6 | Allen-Bradley | Thermocouple Input Module In Stock
Manufacturer: Allen Bradley
-
Part Number: 1769-IT6
Condition:New with Original Package
Product Type: Thermocouple Input Module
-
Country of Origin: USA
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
Allen-Bradley 1769-IT6 Thermocouple Input Module
Product Overview
The Allen-Bradley 1769-IT6 is a thermocouple input module designed for precise temperature measurement in industrial applications. It supports six RTD inputs and two cold junction compensation (CJC) sensors, accommodating a variety of thermocouple types including B, E, J, K, R, S, T, N, and C. The module's high-resolution capabilities and sigma delta converter type ensure accurate temperature readings, making it suitable for demanding environments that require reliable thermal monitoring.
Specifications
- Manufacturer: Allen-Bradley
- Product No.: 1769-IT6
- Product Type: Thermocouple Input Module
-
Inputs:
- 6 RTD inputs
- 2 CJC sensors
- Thermocouples Supported: B, E, J, K, R, S, T, N, C
- Resolution: Input filter and configuration dependent
- Converter Type: Sigma Delta
-
Bus Current Draw:
- 5V DC: 140 mA
- 24V DC: 30 mA
- Heat Dissipation, Max: 1.5 W
- Common Mode Voltage Range: ±10V DC max
- Rated Working Voltage: 30V AC/30V DC
- CJC Assembly Accuracy: ±1.0 °C (±1.8 °F)
- Nonlinearity: ±0.03% of full scale
- Open-Circuit Detection Time: 7 ms to 2.1 s
- Power Supply Compatibility: 1769-PA2, 1769-PB2, 1769-PA4, 1769-PB4
- Power Supply Distance Rating: Up to 8 modules
- Slot Width: 1 slot
- Dimensions (LxWxH): 8.7 cm x 3.5 cm x 11.8 cm
- Weight: 2 kg
- Shipping Weight: 3 kg
Features
- Versatile Input Support: Equipped with six RTD inputs and two CJC sensors, supporting multiple thermocouple types for flexible temperature measurement.
- High Precision: Utilizes a sigma delta converter for high-resolution data acquisition, ensuring accurate temperature sensing.
- Cold Junction Compensation: Includes CJC sensors with an accuracy of ±1.0 °C, enhancing the reliability of thermocouple measurements.
- Low Nonlinearity: Maintains a low nonlinearity of ±0.03%, contributing to highly accurate readings across the measurement range.
- Efficient Power Management: Designed to draw minimal current from the bus power supply, reducing energy consumption.
- Robust Design: Capable of dissipating up to 1.5 W of heat, ensuring stable operation under varying conditions.
- Compact Size: Fits into a single slot width, offering space-efficient integration within control systems.
- Reliable Open-Circuit Detection: Provides rapid detection times ranging from 7 ms to 2.1 s, facilitating timely identification of open circuits.