Honeywell 8C-PAIMA1 Low Level Analog Input Module
Honeywell 8C-PAIMA1 Low Level Analog Input Module
Honeywell 8C-PAIMA1 Low Level Analog Input Module
/ 3

Honeywell 8C-PAIMA1 Low Level Analog Input Module

  • Manufacturer: Honeywell

  • Part Number: 8C-PAIMA1

  • Condition:New with Original Package

  • Product Type: Analog Input Module

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

Specifications

  • Input Type: Thermocouple and/or RTD
  • Voltage Rating: 24 VDC
  • Module Current Rating: 120 mA
  • Temperature:
    • Operating Temperature: 0 to 60 ℃
    • Storage Temperature: -40 to 85 ℃
  • Module Removal and Insertion: Under Power Supported

Input Channels:

  • 16 fully-isolated channels:
    • Channel-to-channel
    • Channel-to-IOL
    • Channel-to-power supply common in 16 channel increments
  • Input Scan Rate: 1 second fixed by IOM (up to 16 channels/sec max.)
  • Channel Bandwidth: 0 to 4.7 Hz (-3 dB)
  • Nominal Input Range (TC only): -20 to +100 millivolts

Maximum Normal Mode Continuous Input Non-Damaging:

  • -10 to +10 volts (TC)
  • -1 to +2 volts @ 100 milliamps (RTD)
  • Gain Error (-20 to +100 millivolt range): 0.050% full scale max

Temperature Stability:

  • TC, Millivolt Inputs: ±20 ppm per ℃ max
  • RTD Inputs: ±20 ppm per ℃ max
  • Long Term Drift: 500 ppm

Input Impedance:

  • 1 megohm at DC (TC only)

Common Mode Voltage (CMV) with Respect to Power System Common:

  • DC to 60 Hz: +/-250 VDC or VAC RMS

Channel to Shield:

  • +/-250 VDC or VAC RMS

Channel to Channel:

  • +/-33 VDC or VAC RMS

CMRR, 50 or 60 Hz (with 1000 ohms source impedance max.): 120 dB min

Voltage, Channel-to-Channel, DC to 60 Hz:

  • +/-250 VDC or VAC RMS

Crosstalk, DC to 60 Hz: 80 dB (120 dB at 50 and 60 Hz)

NMRR at 50/60 Hz: 60 dB min

Line Frequency Integration: Fixed selection of 50 Hz or 60 Hz

RTD Sensor Excitation Current: 1 milliamp

Cold Junction Compensation Range: -20 to +60 ℃ (±0.5 ℃ typical)

TC Linearization Accuracy: ±0.05 Ω / ℃

Open Thermocouple Detection:

  • Each conversion qualified
  • ≤ 1000 Ω = guaranteed no-trip
  • ≥ 1500 Ω guaranteed trip.

RTD Max Lead Resistance: 15 Ω

Surge Protection (Sensor Terminals):

  • EN 61000-4-5 (for Industrial locations)
    • 1kV line to line
    • 2kV line to ground

Surge Protection (Power/Serial Link with Cable Adapter Option):

  • EN 61000-4-5 (for Industrial locations)
    • 1kV line to line
    • 2kV line to ground